ESD Flooring

ESD (Electrostatic Discharge) flooring is an engineered resin system built to control and safely dissipate static charge to earth, protecting sensitive electronics, ignition-risk areas, and controlled environments. POLYZEN engineers each ESD floor as a complete grounded system — from a conductive copper-grid network to the static-control finish — for electronics manufacturing, data centres, defence, and explosive-atmosphere facilities.

How a POLYZEN ESD floor is built

01

Survey & Mechanical Preparation

Diamond grinding or shot-blasting removes the weak laitance layer and opens the concrete profile for a true mechanical bond.

02

Conductive Priming

A conductive primer is applied to create a uniform charge-carrying base across the prepared slab.

03

Copper Earthing Grid

A copper-strip grounding network is laid and connected to the building earth — the path that carries static charge safely away.

04

Static-Control Build-Up

The defining layer — a dissipative or conductive resin body engineered to a controlled electrical resistance.

05

Finish & Seal

A static-control topcoat that locks in the floor's electrical performance and surface durability.

06

Test, Cure & Handover

Surface-resistance testing to verify electrical performance, controlled cure, and staged return-to-service.

ESD flooring systems

Which ESD floor do you need?

Your requirement
Recommended system
General electronics & ESD-protected assembly
Anti-Static (Dissipative) ESD Flooring
Highest static sensitivity & ignition-risk areas
Conductive ESD Flooring
Establishing the earthing path for the floor
Earthing & Grounding Integration
Data centres & server halls
Anti-Static / Conductive (per spec)
Defence, munitions & explosive atmospheres
Conductive ESD Flooring

Sectors we serve

Electronics ManufacturingData Centres & Server RoomsDefence & MunitionsPharmaceutical & Life SciencesTelecommunicationsAerospaceIndustrial Manufacturing

Frequently asked questions

What is ESD flooring?

An engineered resin floor system that controls and safely dissipates static electricity to earth, protecting sensitive electronics, equipment, and ignition-risk environments.

What is the difference between dissipative and conductive ESD flooring?

Dissipative floors discharge static at a slower, controlled rate, while conductive floors offer the lowest resistance and fastest path to earth for the most static-sensitive areas. The right choice depends on the facility's electrical specification.

Why does an ESD floor need a copper earthing grid?

The copper-strip grid connected to the building earth is what actually carries the static charge away — without a properly bonded grounding network, a static-control resin alone cannot do its job.

Where is ESD flooring required?

In electronics manufacturing, data centres, defence and munitions facilities, telecom, aerospace, and any area where static discharge can damage equipment or create an ignition risk.

Is the floor's electrical performance tested?

Yes — surface-resistance testing is carried out to verify the floor meets the required electrical performance before handover.

Which ESD system is right for my facility?

It depends on your static-sensitivity level, applicable standards, and risk environment — POLYZEN surveys the site and engineers the correct dissipative or conductive system.