The ZENSTAT Range
ZENSTAT is POLYZEN's range of ESD (electrostatic discharge) control flooring systems, available in three formulated grades — Prime, Dissipative, and Conductive. Each is a pre-measured kit engineered to control static for a specific level of sensitivity, from grounded base systems to fully conductive floors for the most demanding electronics and hazardous environments.
Three Systems, One Standard
ZENSTAT Prime
A static-control base system with integrated earthing — the conductive primer and copper-grid groundwork that anchors a complete ESD floor to a reliable discharge path.
- ESD groundwork & earthing integration
- Conductive primer + copper grid
- Foundation for dissipative / conductive coats
ZENSTAT Dissipative
A static-dissipative epoxy that bleeds charge away in a controlled, resistive path — protecting sensitive electronics and meeting standard ESD-controlled area requirements.
- Electronics assembly & ESD-controlled areas
- Controlled, resistive discharge
- Resistance range per TDS
ZENSTAT Conductive
A fully conductive epoxy providing the lowest-resistance, fastest discharge path — built for the most static-sensitive electronics and hazardous or explosive-risk environments.
- Hazardous, defence & critical electronics
- Fastest, lowest-resistance discharge
- Maximum static control (Per TDS)
Compare the Range
| System | ZENSTAT Prime | ZENSTAT Dissipative | ZENSTAT Conductive |
|---|---|---|---|
| Product Code | ZS-100 | ZS-200 | ZS-300 |
| ESD Function | Earthing base | Static dissipative | Fully conductive |
| System Type | Conductive primer + grid | Dissipative epoxy | Conductive epoxy |
| Discharge Path | Grounding network | Controlled / resistive | Direct / low-resistance |
| Static Control Level | Foundation | Standard | Maximum |
| Resistance Range | Per TDS | Per TDS | Per TDS |
| Best Suited For | ESD groundwork | Electronics, ESD areas | Hazardous, critical electronics |
| Technical Data | Per TDS | Per TDS | Per TDS |
Which ZENSTAT System Should You Choose?
The right system depends on your sensitivity level and the standard you must meet. Use this quick guide — or request a free ESD assessment and we'll specify it for you.
For projects that need the conductive primer, copper grid and grounding network every ESD floor is built on.
For electronics assembly, server rooms and labs needing a controlled, static-dissipative floor.
For the most static-sensitive electronics and hazardous or explosive-risk zones needing a fully conductive floor.
ZENSTAT — Common Questions
They are not interchangeable words, they are different resistance bands. A static-dissipative floor sits in the 10 to the 6 to 10 to the 9 ohm band, and a conductive floor at 10 to the 6 ohm and below, with values per the product TDS. Anti-static on its own usually only describes reduced tribocharging and is not a measured band at all. The distinction is explained in ESD versus anti-static versus conductive flooring.
That is set by the standard your operation works to, not by preference. IEC 61340-5-1 and ANSI ESD S20.20 define the ESD control programme and the limits that apply to flooring within it, and an electronics assembly line, a panel room and an explosives magazine can land in different bands. POLYZEN supplies systems that support compliance with these standards; the qualifying measurement is taken on the finished installed floor.
By measurement on the completed floor, not by a claim on a datasheet. Resistance is measured point to point and point to ground under defined conditions, because humidity, cleaning residue and even footwear change the reading. Our ESD resistance checker shows which band a measured value falls into.
Prime is the base and earthing groundwork layer, and is described as anti-static framing only. It is the preparation and grounding side of an ESD floor rather than the conductive or dissipative wearing layer itself, and it is specified together with the system above it.
Only if it is maintained and re-tested. The commonest cause of a failing ESD floor is not the resin but the cleaning: the wrong polish, sealer or residue can insulate the surface and take a compliant floor out of band without any visible change. Periodic measurement is part of owning one.
Sometimes, but the earthing design has to be worked out for that build-up, and the existing surface has to be tested and mechanically prepared. An ESD system installed over an unsuitable base can measure correctly on the day and drift out of band later.
An ESD floor is priced as a system, not a coating: the earthing groundwork, the conductive or dissipative layer and the verification measurement all sit inside the scope. For an indicative budget in about two minutes, without a call, use CostMyFloor. A firm quotation follows a site survey.
Specify the Right ZENSTAT System
Tell us your sensitivity level, standards and area — we'll recommend and quote the exact ESD system.