IT Parks
& Data CentresESD-CONTROLLED · GROUNDED · SEAMLESS
Static-dissipative and conductive ESD flooring with integrated earthing — engineered to protect server halls, equipment rooms and network infrastructure, with seamless epoxy for offices and circulation.
Flooring for IT Parks & Data Centres
Server halls, UPS rooms and network spaces hold equipment where a single static discharge can corrupt data or destroy hardware. The defining requirement here is controlled electrostatic discharge — measured, grounded and stable over years. POLYZEN engineers static-dissipative and conductive ESD floors with integrated earthing for critical zones, and seamless epoxy for the offices and circulation that surround them.
What a Data Centre Floor Must Deliver
Every requirement below maps to equipment protection or facility uptime — not a cosmetic one.
Static Dissipation
Controlled resistance to bleed away charge and protect sensitive electronics.
Earthing & Grounding
Integrated copper-grid network bonded to the building earth for reliable discharge.
Low Particle Shedding
Non-dusting, non-flaking surfaces that keep equipment air clean.
Surface Cleanability
Seamless, jointless finishes for dust-free halls and easy maintenance.
Durability Under Load
Withstands server racks, CRAC units and heavy equipment trolleys.
Resistance Stability
Consistent electrical performance across temperature, humidity and time.
Seamless Finish
Jointless surfaces that resist contamination and simplify cleaning.
Phased Installation
Sequenced application to suit live, occupied and uptime-critical facilities.
Engineered to Support ESD & Facility Standards
POLYZEN ESD systems are specified to support the electrostatic and facility frameworks data centres are audited against.
IEC 61340-5-1
Supports ESD-protected-area (EPA) requirements in server and equipment halls.
ANSI/ESD S20.20
Supports static-control program management for electronics-handling spaces.
TIA-942
Supports data-centre facility infrastructure with durable, low-maintenance surfaces.
ISO 14644
Supports controlled-particle environments where clean-zone conditions are required.
Fire & Safe Egress
Supports low-shedding, demarcated walkway and egress surfaces.
Electrical performance values (Rg, Rp and related ESD resistances) are stated Per TDS. POLYZEN supplies and applies ESD flooring engineered to support facility static-control programs; certification and qualification of the EPA remain with the operator.
The Right System for Each Zone
An IT park is not one floor — critical halls demand ESD control, while offices need durable epoxy. POLYZEN specifies zone-by-zone.
| Zone | Primary Demand | Recommended System |
|---|---|---|
| Server Halls / White Space | Static dissipation, low shedding | ZENSTAT DissipativeZS-200 |
| UPS / Battery Rooms | Grounding, acid resistance | ZENSTAT ConductiveZS-300 |
| Network / Equipment Rooms | Static control, cleanability | ZENSTAT DissipativeZS-200 |
| NOC / Control Rooms | ESD control, comfort | ZENSTAT DissipativeZS-200 |
| Electrical / Switchgear | Grounding, durability | ZENSTAT ConductiveZS-300 |
| Offices / Workspace | Durability, finish, traffic | ZENFLOR ProZF-300 |
| Corridors / Circulation | Seamless, high-traffic wear | ZENFLOR ProZF-300 |
| Loading / Service Areas | Abrasion, traffic | ZENFLOR SovereignZF-500 |
POLYZEN Systems for IT Parks & Data Centres
Manufacturer-formulated, applied as turnkey. Every system carries its own Technical Data Sheet.
ZENSTAT Dissipative
Static-dissipative floor — server halls & equipment rooms→ ZS-300 · ESDZENSTAT Conductive
Grounded conductive floor — UPS, battery & switchgear→ ZS-100 · ESD BASEZENSTAT Prime
ESD base & copper-grid earthing groundwork→ ZF-300 · EPOXYZENFLOR Pro
Self-leveling epoxy — offices, circulation & common areas→Applied Flooring Services
Turnkey installation — survey, substrate preparation, application and warranty.
From Survey to Validated Floor
Inspect & Assess
Substrate survey, moisture (MVT) testing and zone-by-zone ESD requirement mapping.
Specify
System selection per zone, with earthing layout, BOQ, ITP and specification support.
Apply
Mechanically Prepared / Ground / Shot-Blasted substrate, copper-grid earthing, then ESD build-up.
Validate & Warrant
Resistance verification, handover documentation and written system warranty.
Technical Documentation
Specification-ready documents for engineers, consultants and QA teams.
IT Park & Data Centre Flooring — FAQ
Planning a data centre or IT park floor?
Share your critical zones and POLYZEN will specify the right ESD and epoxy systems — survey to warranty.