POLYZEN SECTOR · IT PARKS & DATA CENTRES

IT Parks
& Data CentresESD-CONTROLLED · GROUNDED · SEAMLESS

Static-dissipative and conductive ESD flooring with integrated earthing — engineered to protect server halls, equipment rooms and network infrastructure, with seamless epoxy for offices and circulation.

ESD READYEPA · IEC 61340
FACILITY REFERENCE VISUAL CONCEPT RENDER — TO BE ADDED
ESD-ControlledServer & Equipment Halls
Earthing-IntegratedCopper-Grid Grounding
Low-SheddingSeamless & Cleanable
TurnkeySurvey to Warranty
01
OVERVIEW

Flooring for IT Parks & Data Centres

Server halls, UPS rooms and network spaces hold equipment where a single static discharge can corrupt data or destroy hardware. The defining requirement here is controlled electrostatic discharge — measured, grounded and stable over years. POLYZEN engineers static-dissipative and conductive ESD floors with integrated earthing for critical zones, and seamless epoxy for the offices and circulation that surround them.

Static-dissipative & conductive Copper-grid earthing Low particle shedding Seamless & cleanable
02
INDUSTRY REQUIREMENTS

What a Data Centre Floor Must Deliver

Every requirement below maps to equipment protection or facility uptime — not a cosmetic one.

01

Static Dissipation

Controlled resistance to bleed away charge and protect sensitive electronics.

02

Earthing & Grounding

Integrated copper-grid network bonded to the building earth for reliable discharge.

03

Low Particle Shedding

Non-dusting, non-flaking surfaces that keep equipment air clean.

04

Surface Cleanability

Seamless, jointless finishes for dust-free halls and easy maintenance.

05

Durability Under Load

Withstands server racks, CRAC units and heavy equipment trolleys.

06

Resistance Stability

Consistent electrical performance across temperature, humidity and time.

07

Seamless Finish

Jointless surfaces that resist contamination and simplify cleaning.

08

Phased Installation

Sequenced application to suit live, occupied and uptime-critical facilities.

03
STANDARDS & COMPLIANCE

Engineered to Support ESD & Facility Standards

POLYZEN ESD systems are specified to support the electrostatic and facility frameworks data centres are audited against.

TIER 1 · ESD

IEC 61340-5-1

Supports ESD-protected-area (EPA) requirements in server and equipment halls.

TIER 1 · ESD

ANSI/ESD S20.20

Supports static-control program management for electronics-handling spaces.

TIER 2 · DATA CENTRE

TIA-942

Supports data-centre facility infrastructure with durable, low-maintenance surfaces.

TIER 2 · CLEANLINESS

ISO 14644

Supports controlled-particle environments where clean-zone conditions are required.

TIER 3 · SAFETY

Fire & Safe Egress

Supports low-shedding, demarcated walkway and egress surfaces.

Electrical performance values (Rg, Rp and related ESD resistances) are stated Per TDS. POLYZEN supplies and applies ESD flooring engineered to support facility static-control programs; certification and qualification of the EPA remain with the operator.

04
CRITICAL ZONES MAP

The Right System for Each Zone

An IT park is not one floor — critical halls demand ESD control, while offices need durable epoxy. POLYZEN specifies zone-by-zone.

ZonePrimary DemandRecommended System
Server Halls / White SpaceStatic dissipation, low sheddingZENSTAT DissipativeZS-200
UPS / Battery RoomsGrounding, acid resistanceZENSTAT ConductiveZS-300
Network / Equipment RoomsStatic control, cleanabilityZENSTAT DissipativeZS-200
NOC / Control RoomsESD control, comfortZENSTAT DissipativeZS-200
Electrical / SwitchgearGrounding, durabilityZENSTAT ConductiveZS-300
Offices / WorkspaceDurability, finish, trafficZENFLOR ProZF-300
Corridors / CirculationSeamless, high-traffic wearZENFLOR ProZF-300
Loading / Service AreasAbrasion, trafficZENFLOR SovereignZF-500
05
06
07
HOW WE ENGINEER IT

From Survey to Validated Floor

STEP 01

Inspect & Assess

Substrate survey, moisture (MVT) testing and zone-by-zone ESD requirement mapping.

STEP 02

Specify

System selection per zone, with earthing layout, BOQ, ITP and specification support.

STEP 03

Apply

Mechanically Prepared / Ground / Shot-Blasted substrate, copper-grid earthing, then ESD build-up.

STEP 04

Validate & Warrant

Resistance verification, handover documentation and written system warranty.

08
09
FAQ

IT Park & Data Centre Flooring — FAQ

What is the best flooring for a data centre server hall?
Static-dissipative ESD flooring (ZENSTAT Dissipative) is the standard choice for server halls and white space, providing controlled resistance and low particle shedding. Conductive flooring (ZENSTAT Conductive) is used where stricter grounding is required, such as UPS and switchgear rooms.
What is the difference between static-dissipative and conductive ESD flooring?
Dissipative flooring bleeds charge away in a controlled, slower manner and suits most server and equipment halls. Conductive flooring offers a lower-resistance path to earth for the strictest grounding zones. POLYZEN specifies the right one per zone; exact resistance ranges are stated Per TDS.
Does POLYZEN ESD flooring support IEC 61340-5-1 and ANSI/ESD S20.20?
Yes. ZENSTAT systems are engineered to support ESD-protected-area requirements under IEC 61340-5-1 and static-control programs under ANSI/ESD S20.20. Qualification of the EPA itself remains with the operator.
How is ESD flooring earthed and grounded?
An integrated copper-grid earthing network is laid into the system over a conductive primer base (ZENSTAT Prime) and bonded to the building earth, giving the floor a reliable, low-resistance discharge path.
Is ESD flooring required throughout an IT park?
No. ESD flooring is specified only in static-sensitive zones such as server halls, equipment rooms and UPS areas. Offices, circulation and common areas use durable seamless epoxy (ZENFLOR Pro) instead.
Can ESD flooring be installed in a live or occupied facility?
Yes. Installation can be sequenced and phased zone-by-zone to suit uptime-critical and occupied facilities, with surface preparation and curing windows planned around operations.

Planning a data centre or IT park floor?

Share your critical zones and POLYZEN will specify the right ESD and epoxy systems — survey to warranty.